Media & downloads

NYX 450

NYX 450 is available for post top mounting or on arm. Like the other Nyx luminaires, it comes in black and two grey coatings, both suitable for galvanised standard poles. The luminaires are cast in aluminium with shades in clear, hardened glass. 

The Nyx luminaires are equipped with LED with various lens types. The glass shade is parallel to the ground to avoid discomfort glare and light pollution. 

Specifications

NYX 450

nyx-450

Luminaire

NYX 450
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Shade 3 mm hardened glass
Mounting On pole with 60 or 76 mm top diameter, or on 60 or 48 mm arm with an entry depth of 100 mm.
Available with penetrated housing for mid-post mounting
Connection In the pole
Focus provides 9.5 m lead, 2 x 1 mm2, + 2 m for arm
Classification IP66, class II; use code for class I
Impact resistance IK10; with SR socket IK09
Corrosion class C4, C5 optional
Weight 11 kg
Wind-sweeping area 0.09 m2 (laterally)


LED

LED with lenses FF-DA T3 for local roads, P, HS, and C classes, 2, 3, or 4 modules
Operational life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen 2xFF, 70 Ra 3000K: 875-9000 lm
4000K: 950-9700 lm
LED-lumen 2xFF, 80 Ra 2700K: 725-7600 lm
3000K: 775-8000 lm
4000K: 825-8500 lm
LED-lumen 3xFF, 70 Ra 3000K: 1310-13500 lm
4000K: 1420-14600 lm
LED-lumen 3xFF, 80 Ra 2700K: 1100-11400 lm
3000K: 1175-12000 lm
4000K: 1250-12700 lm
LED-lumen 4xFF, 70 Ra 3000K: 1750-18000 lm
4000K: 1900-19450 lm
LED-lumen 4xFF, 80 Ra 2700K: 1500-15200 lm
3000K: 1550-16000 lm
4000K: 1650-16950 lm
Output ratio 89%
Luminous intensity class, 13201-2-2015 G*3


Driver

Driver 2xFF Xitanium Full Xi FP 75 W 0.2-0.7 A, programmable
Inrush current max 46 A (50% after 250 µs)
Operational input voltage, AC 80-264 Vac

Driver 3xFF Xitanium Full Xi FP 110 W 0.2-0.7 A, programmable
Inrush current max 47 A (50% after 250 µs)
Operational input voltage, AC 80-264 Vac

Driver 4xFF Xitanium Full Xi FP 165 W 0.3-1.0 A, programmable
Inrush current max 41 A (50% after 440 µs)
Operational input voltage, AC 160-264 Vac

Variants and options

 

Item No. Nyx 450 lantern
9930- 2 x FF-DA T3, programmable, max 75 W
9931- 3 x FF-DA T3, programmable, max 114 W
9932- 4 x FF-DA T3, programmable, max 150 W

Options
9023- Wall brackets



Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 730 = 3000 K, 70 Ra
4 = graphite grey 740 = 4000 K, 70 Ra
9 = silver grey 827* = 2700 K, 80 Ra
66 = noir 900 830* = 3000 K, 80 Ra
840* = 4000 K, 80 Ra
* Longer lead times

Mounting Dimming
T = post top empty = programmable
U = side entry Ø60 D = DALI-2 (4/5-conductor cable)
U48 = side entry Ø48 F = LineSwitch
G = mid-column Ø60 R = Zhaga book 18 socket, upwards
G76 = mid-column Ø76 RC = Zhaga book 18 socket, City Touch / Interact City
S = Zhaga book 18 socket, downwards

Protection class Corrosion class
empty = class II empty = C4
J = class I C5 = C5 coating (add C5 after the colour code)


Example Item No.: 9931-01730TJ = Nyx 450 3xFF-DA T3, raw anodized, 3000 K, 70 Ra, post top, class I

nyx-450

Luminaire

NYX 450
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Shade 3 mm hardened glass
Mounting On pole with 60 or 76 mm top diameter, or on 60 or 48 mm arm with an entry depth of 100 mm.
Available with penetrated housing for mid-post mounting
Connection In the pole
Focus provides 9.5 m lead, 2 x 1 mm2, + 2 m for arm
Classification IP66, class II; use code for class I
Impact resistance IK10; with SR socket IK09
Corrosion class C4, C5 optional
Weight 11 kg
Wind-sweeping area 0.09 m2 (laterally)


LED

LED with lenses FF-DA MEW for traffic roads, M classes, 2, 3, or 4 modules
Operational life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen, 2xFF, 70 Ra 3000K: 875-9000 lm
4000K: 950-9700 lm
LED-lumen, 2xFF, 80 Ra 2700K: 725-7600 lm
3000K: 775-8000 lm
4000K: 825-8500 lm
LED-lumen, 3xFF, 70 Ra 3000K: 1310-13500 lm
4000K: 1420-14600 lm
LED-lumen, 3xFF, 80 Ra 2700K: 1100-11400 lm
3000K: 1175-12000 lm
4000K: 1250-12700 lm
LED-lumen, 4xFF, 70 Ra 3000K: 1750-18000 lm
4000K: 1900-19450 lm
LED-lumen, 4xFF, 80 Ra 2700K: 1500-15200 lm
3000K: 1550-16000 lm
4000K: 1650-16950 lm
Output ratio 92%
Luminous intensity class, 13201-2-2015 G*6


Driver

Driver 2xFF Xitanium Full Xi FP 75 W 0.2-0.7 A, programmable
Inrush current max 46 A (50% after 250 µs)
Operational input voltage, AC 80-264 Vac

Driver 3xFF Xitanium Full Xi FP 110 W 0.2-0.7 A, programmable
Inrush current max 47 A (50% after 250 µs)
Operational input voltage, AC 80-264 Vac

Driver 4xFF Xitanium Full Xi FP 165 W 0.3-1.0 A, programmable
Inrush current max 41 A (50% after 440 µs)
Operational input voltage, AC 160-264 Vac

Variants and options

 

Item No. Nyx 450 lantern
9950- 2 x FF-DA MEW, programmable, max 75 W
9951- 3 x FF-DA MEW, programmable, max 114 W
9952- 4 x FF-DA MEW, programmable, max 150 W

Options
9023- Wall brackets



Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 730 = 3000 K, 70 Ra
4 = graphite grey 740 = 4000 K, 70 Ra
9 = silver grey 827* = 2700 K, 80 Ra
66 = noir 900 830* = 3000 K, 80 Ra
840* = 4000 K, 80 Ra
* Longer lead times

Mounting Dimming
T = post top empty = programmable
U = side entry Ø60 D = DALI-2 (4/5-conductor cable)
U48 = side entry Ø48 F = LineSwitch
G = mid-column Ø60 R = Zhaga book 18 socket, upwards
G76 = mid-column Ø76 RC = Zhaga book 18 socket, City Touch / Interact City
S = Zhaga book 18 socket, downwards

Protection class Corrosion class
empty = class II empty = C4
J = class I C5 = C5 coating (add C5 after the colour code)


Example Item No.: 9952-9730UJ = Nyx 450 4xFF-DA MEW, silver grey, 3000 K, 70 Ra, for arm, class I

nyx-450

Luminaire

NYX 450
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Shade 3 mm hardened glass
Mounting On pole with 60 or 76 mm top diameter, or on 60 or 48 mm arm with an entry depth of 100 mm.
Available with penetrated housing for mid-post mounting
Connection In the pole
Focus provides 9.5 m lead, 2 x 1 mm2, + 2 m for arm
Classification IP66, class II; use code for class I
Impact resistance IK10; with SR socket IK09
Corrosion class C4, C5 optional
Weight 11 kg
Wind-sweeping area 0.09 m2 (laterally)


LED

LED with lenses FF-DA T4 for roundabouts, 2, 3, or 4 modules
Operational life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen, 2xFF, 70 Ra 3000K: 875-9000 lm
4000K: 950-9700 lm
LED-lumen, 2xFF, 80 Ra 2700K: 725-7600 lm
3000K: 775-8000 lm
4000K: 825-8500 lm
LED-lumen, 3xFF, 70 Ra 3000K: 1310-13500 lm
4000K: 1420-14600 lm
LED-lumen, 3xFF, 80 Ra 2700K: 1100-11400 lm
3000K: 1175-12000 lm
4000K: 1250-12700 lm
LED-lumen, 4xFF, 70 Ra 3000K: 1750-18000 lm
4000K: 1900-19450 lm
LED-lumen, 4xFF, 80 Ra 2700K: 1500-15200 lm
3000K: 1550-16000 lm
4000K: 1650-16950 lm
Output ratio 90%
Luminous intensity class, 13201-2-2015 G*2


Driver

Driver 2xFF Xitanium Full Xi FP 75 W 0.2-0.7 A, programmable
Inrush current max 46 A (50% after 250 µs)
Operational input voltage, AC 80-264 Vac

Driver 3xFF Xitanium Full Xi FP 110 W 0.2-0.7 A, programmable
Inrush current max 47 A (50% after 250 µs)
Operational input voltage, AC 80-264 Vac

Driver 4xFF Xitanium Full Xi FP 165 W 0.3-1.0 A, programmable
Inrush current max 41 A (50% after 440 µs)
Operational input voltage, AC 160-264 Vac

Variants and options

 

Item No. Nyx 450 lantern
9940- 2 x FF-DA T4, programmable, max 75 W
9941- 3 x FF-DA T4, programmable, max 114 W
9942- 4 x FF-DA T4, programmable, max 150 W

Options
9023- Wall brackets



Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 730 = 3000 K, 70 Ra
4 = graphite grey 740 = 4000 K, 70 Ra
9 = silver grey 827* = 2700 K, 80 Ra
66 = noir 900 830* = 3000 K, 80 Ra
840* = 4000 K, 80 Ra
* Longer lead times

Mounting Dimming
T = post top empty = programmable
U = side entry Ø60 D = DALI-2 (4/5-conductor cable)
U48 = side entry Ø48 F = LineSwitch
G = mid-column Ø60 R = Zhaga book 18 socket, upwards
G76 = mid-column Ø76 RC = Zhaga book 18 socket, City Touch / Interact City
S = Zhaga book 18 socket, downwards

Protection class Corrosion class
empty = class II empty = C4
J = class I C5 = C5 coating (add C5 after the colour code)


Example Item No.: 9941-9730TJ = Nyx 450 3xFF-DA T4, silver grey, 3000 K, 70 Ra, post top, class I

nyx-450

Luminaire

NYX 450
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Shade 3 mm hardened glass
Mounting On pole with 60 or 76 mm top diameter, or on 60 or 48 mm arm with an entry depth of 100 mm.
Available with penetrated housing for mid-post mounting.
Connection In the pole
Focus provides 9.5 m lead, 2 x 1 mm2, + 2 m for arm
Classification IP66, class II; use code for class I
Impact resistance IK10; with SR socket IK09
Corrosion class C4, C5 optional
Weight 11 kg
Wind-sweeping area 0.09 m2 (laterally)


LED

LED with lenses FF-DA PX for pedestrian crossings, 2 or 3 modules
Operational life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen, 2xFF, 70 Ra 3000K: 875-9000 lm
4000K: 950-9700 lm
LED-lumen, 2xFF, 80 Ra 2700K: 725-7600 lm
3000K: 775-8000 lm
4000K: 825-8500 lm
LED-lumen, 3xFF, 70 Ra 3000K: 1310-13500 lm
4000K: 1420-14600 lm
LED-lumen, 3xFF, 80 Ra 2700K: 1100-11400 lm
3000K: 1175-12000 lm
4000K: 1250-12700 lm
Output ratio 89%
Luminous intensity class, 13201-2-2015 G*4


Driver

Driver 2xFF Xitanium Full Xi FP 75 W 0.2-0.7 A, programmable
Inrush current max 46 A (50% after 250 µs)

Driver 3xFF Xitanium Full Xi FP 110 W 0.2-0.7 A, programmable
Inrush current max 47 A (50% after 250 µs)

Operational input voltage, AC 80-264 Vac
Nominal voltage, AC 220-240 Vac
Nominal voltage, DC 186-250 Vdc
Operational input voltage, DC 168-275 Vdc
Nominal input frequency 50-60 Hz
Operational input frequency 45-66 Hz
Max preprotection 16 A
Surge protection L/N-GND: 10 kV
L-N: 6 kV
Service life min 100,000 hours
Dimming/control 5 steps dimming within the lumen intervals
Other control options DALI-2, LineSwitch or
via Zhaga book 18 socket, D4i

Variants and options

 

Item No. Nyx 450 lantern
9955- 2 x FF-DA PX, programmable, max 75 W
9956- 3 x FF-DA PX, programmable, max 114 W

Options
9023- Wall brackets



Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 730 = 3000 K, 70 Ra
4 = graphite grey 740 = 4000 K, 70 Ra
9 = silver grey 827* = 2700 K, 80 Ra
66 = noir 900 830* = 3000 K, 80 Ra
840* = 4000 K, 80 Ra
* Longer lead times

Mounting Dimming
T = post top empty = programmable
U = side entry Ø60 D = DALI-2 (4/5-conductor cable)
U48 = side entry Ø48 F = LineSwitch
G = mid-column Ø60 R = Zhaga book 18 socket, upwards
G76 = mid-column Ø76 RC = Zhaga book 18 socket, City Touch / Interact City
S = Zhaga book 18 socket, downwards

Protection class Corrosion class
empty = class II empty = C4
J = class I C5 = C5 coating (add C5 after the colour code)


Example Item No.: 9955-9730UJ = Nyx 450 2xFF-DA PX, silver grey, 3000 K, 70 Ra, for arm, class I

Media & downloads

Photometric data

All ldt files

nyx450_svendborgteaser_1166

LED light in Svendborg Kommune

More Photos
nyx450_nat_svendborg_1166

Nyx 450 in Svendborg Kommune

More photos
nyx450_hasselager_1166

Nyx 450, Hasselager, Aarhus Kommune

nyx450_hasselagerkirke_1166

Nyx 450, Hasselager, Aarhus Kommune

nyx450_roende_l4_1166

Nyx 450 at the main street in Rønde, Syddjurs Kommune

More photos
nyx450_roende_dec2_1166

Nyx 450 at the main street in Rønde, Syddjurs Kommune

More photos
nyx450_toender14_1166

Roundabout, Tønder

More photos from Tønder.
nyx450_toender10_1166

Roundabout, Tønder

More photos from Tønder.
nyx450_odense_1166

Nyx 450, roundabout in Odense.

More photos here
skbsyd_40729_1166

Nyx 450 at 8 m column, Østjyske motorway TSA 51, Skanderborg South

skbsyd_41325_1166

Nyx 450 at 8 m column, Østjyske motorway TSA 51, Skanderborg South

skbsyd_43723_1166

Nyx 450 at 8 m column, Østjyske motorway TSA 51, Skanderborg South

nyx450_hedensted_1166

Nyx 450 at roundabout in Hedensted

nyxmaster_egtved_1166

Nyx 450 and Nyx 330 at the Egtved gas compresser station

nyx450_sauersplads_1166

Nyx 450 on angled pole, Sauers Square, Aalborg

More photos
nyx_gellerup_1141_1166

Nyx 450, Gellerup, Aarhus

nyx450_gellerup_4536_1166

Nyx 450, Gellerup, Aarhus

nyx450_thisted_115954_1166

Nyx 450 side entry, Thisted Kystvej

DesignVilhelm Lauritzen Architects

Our succes in street lighting is primarily due to the Nyx luminaires, designed by Vilhelm Lauritzen Architects in 2005.

The large lantern, NYX 450, is suitable for tall poles. It can be seen at the outdoor test centre, Living Lab at Hersted Industripark. More about the Living Lab here.