Nyx 330 is available for post or wall mounting. Like the other fittings in the Nyx family, it comes in black and two grey shades, both of which will fit galvanised standard poles.
The Nyx 330 post-top luminaire is suitable for 3 to 6 meter columns. The luminaire will fit any post type with a top diameter of 60 mm.
Multiple Nyx variants are available for cylindrical columns, Ø60 mm.
NYX 330 LANTERN | |
---|---|
Material | Cast aluminium |
Finish | Raw anodized |
Graphite grey: YW355F, Akzo Nobel | |
Silver grey: Y2370I, Akzo Nobel | |
Black: RAL 9005, SN805G, Akzo Nobel | |
Black: Noir 900 Sablé, SN351F, Akzo Nobel | |
Corten brown: YX355F, Akzo Nobel | |
Shade | UV-resistant polycarbonate, frosted |
Mounting | On pole with 60 mm top diameter |
Multiple Nyx | Available with penetrated housing for several luminaires on 60 mm pole. See data at Media & downloads below. |
Connection | In the column |
Focus provides 5.5 m lead 2 x 1 mm2 | |
Classification | IP65, class II; use code for class I |
Impact resistance | IK10; with SR socket IK09 |
Corrosion class | C4, C5 optional |
Weight | 6.5 kg |
Wind-sweeping area | 0.053 m2 (laterally) |
LED with lenses | FF-DA T3 for local roads, P, HS, and C classes |
---|---|
Service life | min 100,000 hours at ta max 25° C, L100B10 |
Constant lumen output | |
Temperature range | -30 to +35° C |
Colour temperature | View configurator |
Colour rendering | View configurator |
Colour accuracy | 5 steps SDCM |
LED with lenses | FF-DA T3 for local roads, P, HS, and C classes |
---|---|
Service life | min 100,000 hours at ta max 25° C, L100B10 |
Constant lumen output | |
Temperature range | -30 to +35° C |
Colour temperature | View configurator |
Colour rendering | View configurator |
Colour accuracy | 5 steps SDCM |
Driver, Low lumen | Xitanium Full Xi FP 22 W 0,2-0,7 A, programmable |
---|---|
Inrush current | max 15 A (50% after 295 µs) |
Driver, High lumen | Xitanium Full Xi FP 40 W 0,2-0,7 A, programmable |
---|---|
Inrush current | max 22 A (50% after 290 µs) |
Nominal voltage, AC | 220-240 Vac |
Operational input voltage, AC | 80-264 Vac |
Nominal voltage, DC | 186-250 Vdc |
Operational input voltage, DC | 168-275 Vdc |
Nominal frequency range | 50-60 Hz |
Operational frequency range | 45-66 Hz |
Max pre-protection | 16 A |
Surge protection | L/N-GND: 10 kV, (D4i driver: 8 kV) |
L-N: 6 kV | |
Operational life | min 100,000 hours |
Dimming/control | 5 steps dimming within the lumen intervals |
Other control options | DALI-2, LineSwitch or |
via Zhaga book 18 socket, D4i |
The story of Nyx begins in 2004 when Vilhelm Lauritzen Architects present the first draft for a wall fitting in two sizes. The design was simple, but characteristic and easily recognisable. Furthermore, Nyx differed from other luminaires of the time by the fact that it is cast in aluminium. Soon the series grew by lanterns and bollards, and especially the lanterns have shown great potential in street lighting.