Media & downloads

NYX BOLLARD

Please choose

Nyx is a range of exterior fittings for wall, bollard, or pole mounting. NYX is the answer to today’s demands for pleasant and well-defined light directed to the place where light is required.

The Nyx 190 fitting can be mounted on wall or bollard.  

Specifications

NYX 190

nyx-190

Luminaire

NYX 190
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: RAL 9005, SN805G, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Corten brown: YX355F, Akzo Nobel
Shade Frosted polycarbonate
Mounting On wall or special pole, double cable entry
Option for base for visible installation
Connection Max two cables into 5 x 2.5 mm2 terminal block
Classification IP66, class I or II
Impact resistance IK10
Corrosion class C4, C5 optional
Weight 2.6 kg


LED and driver data

LED type 2 x Bridgelux V6
Total consumption 6, 8, 11, or 16 W
Operational life min 100,000 hours at ta max 25°C, L90B10
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 90 Ra
Colour accuracy 3 steps SDCM
Output ratio 59%

Standard driver LED driver, 20 W
Dimming optional
Inrush current max 5 A (50% after 50 µs)
Operational life min 100,000 hours

Programmable driver Xitanium Full Xi FP 22 W, 0.3-1.0 A
Inrush current max 14 A (50% after 400 µs)
Dimming 5 steps dimming within the lumen intervals
Surge protection L/N-GND: 8 kV, L-N. 6 kV
Operational life min 100,000 hours

Variants and options

 

Item No. Nyx 190
6889- 6 W Bridgelux V6, 250 mA
6841- 8 W Bridgelux V6, 350 mA
6842- 11 W Bridgelux V6, 500 mA
6888- 16 W Bridgelux V6, 700 mA




Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 927 = 2700 K, 90 Ra
3 = black RAL 9005 930 = 3000 K, 90 Ra
4 = graphite grey 940 = 4000 K, 90 Ra
9 = silver grey
17 = corten brown
66 = black noir 900

Dimming Classification
empty = no dimming empty = class I
V = 1-10 V K = class II
D = Dali
E = programmable

Corrosion class
empty = C4
C5 = C5 coating (add C5 after the colour code)


Example Item No.: 6842-66930K = Nyx 190, 11 W LED for bollard mounting, noir 900, 3000 K, 90 Ra, without dimming, class II

nyx-190

Luminaire

NYX 190
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: RAL 9005, SN805G, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Corten brown: YX355F, Akzo Nobel
Shade Frosted polycarbonate
Mounting On wall or special pole, double cable entry
Option for base for visible installation
Connection Max two cables into 5 x 2.5 mm2 terminal block
Classification IP66, class I or II
Impact resistance IK10
Corrosion class C4, C5 optional
Weight 2.6 kg


LED and driver data

LED type Bridgelux Vero 10
Operational life min 100,000 hours at ta max 25° C, L100B10
Total consumption 8, 12, or 16 W
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 90 Ra
Colour accuracy 3 steps SDCM
Output ratio 57%

Driver LED driver, 20 W
Dimming optional
Inrush current max 5 A (50% after 50 µs)
Operational life min 100,000 hours

Variants and options

 

Item No. Nyx 190
6877- 8 W Bridgelux Vero 10, 250 mA
6843- 12 W Bridgelux Vero 10, 350 mA
6844- 16 W Bridgelux Vero 10, 500 mA

Option
60228 Base for visible installation



Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 927 = 2700 K, 90 Ra
3 = black RAL 9005 930 = 3000 K, 90 Ra
4 = graphite grey 940 = 4000 K, 90 Ra
9 = silver grey
17 = corten brown
66 = black noir 900

Dimming Classification
empty = no dimming empty = class I
V = 1-10 V K = class II
D = Dali

Corrosion class
empty = C4
C5 = C5 coating (add C5 after the colour code)


Example Item No.: 6843-9930 = Nyx 190 12 W LED for wall mounting, silver grey, 3000 K, 90 Ra, class I

nyx-190

Luminaire

NYX 190
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: RAL 9005, SN805G, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Corten brown: YX355F, Akzo Nobel
Shade Frosted polycarbonate
Mounting On wall or special pole, double cable entry
Option for base for visible installation
Connection Max two cables into 5 x 2.5 mm2 terminal block
Classification IP66, class I or II
Impact resistance IK10
Corrosion class C4, C5 optional
Weight 2.6 kg


Lamp type

E27 max 57 W, max length 130 mm, max diameter 58 mm
We recommend Deco Aurora LED dimmable, 7.5 W, 2700 K, 20,000 hours operation
Output ratio 39%


Variants and options

 

Item No. Nyx 190
6022- E27, max 57 W, max length 130 mm, max diameter 58 mm

Option
1100-6 A60 Deco Aurora LED dimmable, 7.5 W, 2700 K, 80 Ra, 20,000 hours operation
60228 Base for visible installation



Combine with

Select colour in the table below.

Colour Classification
01 = raw anodized empty = class I
3 = black RAL 9005 K = class II
4 = graphite grey
9 = silver grey
17 = corten brown
66 = black noir 900

Corrosion class
empty = C4
C5 = C5 coating (add C5 after the colour code)



Example Item No.: 6022-4 = Nyx 190 E27, graphite grey, class I

Media & downloads

nyx190_favrholm_1166

Nyx 190 on wall - Favrholm, Hillerød

More photos from Favrholm
nyxpullert_kbh_4054_1166

The Nyx Bollard makes it safe to walk along the lakes in Copenhagen.

More photos from Copenhagen
nyxpullert_kbh_2_1166

Nyx Bollards in Copenhagen grey illuminate the walking areas around the Copenhagen lakes without unwanted glare into the surrounding houses.

More Nyx in Copenhagen
nyx190_hennestr_1166

Nyx 190 at solar cell bollard - Henne Strand

nyx190_norge_1166

Nyx Bollard at college in Norway.

nyxpullert_bagsvd_1166

Nyx bollard 1000 - Bagsværd New School

More photos
nyxpullert_3634_1166

Nyx 190 silver grey - Residences Kastanieparken Hillerød

More photos from Kastanieparken
aften_pullert_8608_1166

Masu Planning, landscape architects, have used the Nyx luminaires in the residence "Bjerglandsbyen" in the Copenhagen suburb Brønshøj; here the Nyx Bollard.

DesignVilhelm Lauritzen Architects

The story of Nyx begins in 2004 when Vilhelm Lauritzen Architects present the first draft for a wall fitting in two sizes. The design was simple, but characteristic and easily recognisable. Furthermore, Nyx differed from other luminaires of the time by the fact that it is cast in aluminium. Soon the series grew by lanterns and bollards, and especially the lanterns have shown great potential in street lighting.

More about Vilhelm Lauritzen Architects here.