Media & downloads

NYX 450

NYX 450 is available for pole top mounting or on arm. Like the other Nyx luminaires it comes in black and two grey coatings, both suitable for galvanised standard poles. The lanterns are cast in aluminium with shades in clear, hardened glass. 

The Nyx luminaires are equipped with LED with various lense types, or with metal halide. The glass shade is parallel to the ground to avoid discomfort glare and light pollution. 

Specifications

NYX 450

nyx-450

Luminaire

NYX 450
Material Cast aluminium
Coating Graphite grey: SW302G (close to RAL 9007)
Silver grey: MW300D
Black: Noir 900 Sablé, SN351F
Shade 3 mm hardened glass
Mounting On pole with 60 or 76 mm top diameter, or on 60 mm arm with an entry depth of 100 mm.
Available with penetrated housing for customized poles.
Connection In the pole
Focus provides 9.5 m lead, 2 x 1 mm2, + 2 m for arm
Classification IP66, class II
Impact resistance IK10
Weight 11 kg
Wind-sweeping area 0.09 m2 (laterally)


LED

LED with lenses FF-DA T3 for local roads, P, HS, and C classes, 2, 3, or 4 modules
Operational life, up to 100 watts min 120,000 hours at ta max 25° C, L80B10
Operational life, 100-160 watts min 100,000 hours at ta max 25° C, L80B10
Temperature range -30 to +35° C
Colour temperature 3000 or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 4 steps SDCM
Luminous power 3000K: 15,000 lm, CLO
4000K: 16,000 lm, CLO
Luminous intensity class, 13201-2-2015 G*4
Output ratio 95%


Driver

Driver 2xFF Xitanium Full Xi FP 75 W 0.2-0.7 A, programmable
Inrush current max 46 A (50% after 250 µs)
Operational input voltage, AC 150-264 Vac

Driver 3xFF and 4xFF Xitanium Full Xi FP 150 W 0.2-0.7 A, programmable
Inrush current max 53 A (50% after 300 µs)
Operational input voltage, AC 150-264 Vac

Nominal voltage, AC 220-240 Vac
Nominal voltage, DC 186-250 Vdc
Operational input voltage, DC 165-275 Vdc
Nominal input frequency 50-60 Hz
Operational input frequency 45-66 Hz
Max preprotection 16 A
Surge protection L/N-GND: 10 kV, (SR driver: 8 kV)
L-N: 6 kV
Service life min 100,000 hours
Dimming/control 8-100% programming range
Other control options DALI, Line switch, AmpDim
DALI via Zhaga book 18 socket

Variants and options

 

Item No. Nyx 450 lantern
9930- 2 x FF-DA T3, max 8,000 lm, programmable, max 75 W
9931- 3 x FF-DA T3, max 12,000 lm, programmable, max 114 W
9932- 4 x FF-DA T3, max 16,000 lm, programmable, max 150 W

Options
90239-2 Wall brackets

Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
4 = graphite grey 730 = 3000 K, 70 Ra
9 = silver grey 740 = 4000 K, 70 Ra
66 = noir 900 830* = 3000 K, 80 Ra
840* = 4000 K, 80 Ra
* Longer lead times

Mounting Dimming
T = post top empty = programmable
U = on arm D = Dali (4-conductor cable)
G = penetrated housing F = Phase (Line switch)
G76 = penetrated Ø76 Z = voltage (AmpDim)
R = Dali via Zhaga book 18 socket

Example Item No.: 9931-9740T = Nyx 450 3xFF-DA T3, silver grey, 4000 K, 70 Ra, top mounting

nyx-450

Luminaire

NYX 450
Material Cast aluminium
Coating Graphite grey: SW302G (close to RAL 9007)
Silver grey: MW300D
Black: Noir 900 Sablé, SN351F
Shade 3 mm hardened glass
Mounting On pole with 60 or 76 mm top diameter, or on 60 mm arm with an entry depth of 100 mm.
Available with penetrated housing for customized poles.
Connection In the pole
Focus provides 9.5 m lead, 2 x 1 mm2, + 2 m for arm
Classification IP66, class II
Impact resistance IK10
Weight 11 kg
Wind-sweeping area 0.09 m2 (laterally)


LED

LED with lenses FF-DA MEW for traffic roads, M classes, 2, 3, or 4 modules
Operational life, up to 100 watts min 120,000 hours at ta max 25° C, L80B10
Operational life, 100-160 watts min 100,000 hours at ta max 25° C, L80B10
Temperature range -30 to +35° C
Colour temperature 3000 or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 4 steps SDCM
Luminous power 3000K: 15,000 lm, CLO
4000K: 16,000 lm, CLO
Luminous intensity class, 13201-2-2015 G*6
Output ratio 98%


Driver

Driver 2xFF Xitanium Full Xi FP 75 W 0.2-0.7 A, programmable
Inrush current max 46 A (50% after 250 µs)
Operational input voltage, AC 150-264 Vac

Driver 3xFF and 4xFF Xitanium Full Xi FP 150 W 0.2-0.7 A, programmable
Inrush current max 53 A (50% after 300 µs)
Operational input voltage, AC 150-264 Vac

Nominal voltage, AC 220-240 Vac
Nominal voltage, DC 186-250 Vdc
Operational input voltage, DC 165-275 Vdc
Nominal input frequency 50-60 Hz
Operational input frequency 45-66 Hz
Max preprotection 16 A
Surge protection L/N-GND: 10 kV, (SR driver: 8 kV)
L-N: 6 kV
Service life min 100,000 hours
Dimming/control 8-100% programming range
Other control options DALI, Line switch, AmpDim
DALI via Zhaga book 18 socket

Variants and options

 

Item No. Nyx 450 lantern
9950- 2 x FF-DA MEW, max 8,000 lm, programmable, max 75 W
9951- 3 x FF-DA MEW, max 12,000 lm, programmable, max 114 W
9952- 4 x FF-DA MEW, max 16,000 lm, programmable, max 150 W

Options
90239-2 Wall brackets

Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
4 = graphite grey 730 = 3000 K, 70 Ra
9 = silver grey 740 = 4000 K, 70 Ra
66 = noir 900 830* = 3000 K, 80 Ra
840* = 4000 K, 80 Ra
* Longer lead times

Mounting Dimming
T = post top empty = programmable
U = on arm D = Dali (4-conductor cable)
G = penetrated housing F = Phase (Line switch)
G76 = penetrated Ø76 Z = voltage (AmpDim)
R = Dali via Zhaga book 18 socket

Example Item No.: 9952-9730U = Nyx 450 4xFF-DA MEW, silver grey, 3000 K, 70 Ra, for arm

nyx-450

Luminaire

NYX 450
Material Cast aluminium
Coating Graphite grey: SW302G (close to RAL 9007)
Silver grey: MW300D
Black: Noir 900 Sablé, SN351F
Shade 3 mm hardened glass
Mounting On pole with 60 or 76 mm top diameter, or on 60 mm arm with an entry depth of 100 mm.
Available with penetrated housing for customized poles.
Connection In the pole
Focus provides 9.5 m lead, 2 x 1 mm2, + 2 m for arm
Classification IP66, class II
Impact resistance IK10
Weight 11 kg
Wind-sweeping area 0.09 m2 (laterally)


LED

LED with lenses FF-DA T4 for roundabouts, 2, 3, or 4 modules
Operational life, up to 100 watts min 120,000 hours at ta max 25° C, L80B10
Operational life, 100-160 watts min 100,000 hours at ta max 25° C, L80B10
Temperature range -30 to +35° C
Colour temperature 3000 or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 4 steps SDCM
Luminous power 3000K: 15,000 lm, CLO
4000K: 16,000 lm, CLO
Luminous intensity class, 13201-2-2015 G*3
Output ratio 96%


Driver

Driver 2xFF Xitanium Full Xi FP 75 W 0.2-0.7 A, programmable
Inrush current max 46 A (50% after 250 µs)
Operational input voltage, AC 150-264 Vac

Driver 3xFF and 4xFF Xitanium Full Xi FP 150 W 0.2-0.7 A, programmable
Inrush current max 53 A (50% after 300 µs)
Operational input voltage, AC 150-264 Vac

Nominal voltage, AC 220-240 Vac
Nominal voltage, DC 186-250 Vdc
Operational input voltage, DC 165-275 Vdc
Nominal input frequency 50-60 Hz
Operational input frequency 45-66 Hz
Max preprotection 16 A
Surge protection L/N-GND: 10 kV, (SR driver: 8 kV)
L-N: 6 kV
Service life min 100,000 hours
Dimming/control 8-100% programming range
Other control options DALI, Line switch, AmpDim
DALI via Zhaga book 18 socket

Variants and options

 

Item No. Nyx 450 lantern
9940- 2 x FF-DA T4, max 8,000 lm, programmable, max 75 W
9941- 3 x FF-DA T4, max 12,000 lm, programmable, max 114 W
9942- 4 x FF-DA T4, max 16,000 lm, programmable, max 150 W

Options
90239-2 Wall brackets

Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
4 = graphite grey 730 = 3000 K, 70 Ra
9 = silver grey 740 = 4000 K, 70 Ra
66 = noir 900 830* = 3000 K, 80 Ra
840* = 4000 K, 80 Ra
* Longer lead times

Mounting Dimming
T = post top empty = programmable
U = on arm D = Dali (4-conductor cable)
G = penetrated housing F = Phase (Line switch)
G76 = penetrated Ø76 Z = voltage (AmpDim)
R = Dali via Zhaga book 18 socket

Example Item No.: 9941-9740T = Nyx 450 3xFF-DA T4, silver grey, 4000 K, 70 Ra, post top

nyx-450

Luminaire

NYX 450
Material Cast aluminium
Coating Graphite grey: SW302G (close to RAL 9007)
Silver grey: MW300D
Black: Noir 900 Sablé, SN351F
Shade 3 mm hardened glass
Mounting On pole with 60 or 76 mm top diameter, or on 60 mm arm with an entry depth of 100 mm.
Available with penetrated housing for customized poles.
Connection In the pole
Focus provides 9.5 m lead, 2 x 1 mm2, + 2 m for arm
Classification IP66, class II
Impact resistance IK10
Weight 11 kg
Wind-sweeping area 0.09 m2 (laterally)


LED

LED with lenses FF-DA PX for pedestrian crossings, 2 or 3 modules
Operational life, up to 100 watts min 120,000 hours at ta max 25° C, L80B10
Operational 100-160 watts min 100,000 hours at ta max 25° C, L80B10
Temperature range -30 to +35° C
Colour temperature 3000 or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 4 steps SDCM
Luminous power 3000K: 11,000 lm, CLO
4000K: 12,000 lm, CLO
Output ratio 94%


Driver

Driver 2xFF Xitanium Full Xi FP 75 W 0.2-0.7 A, programmable
Inrush current max 46 A (50% after 250 µs)
Operational input voltage, AC 150-264 Vac

Driver 3xFF Xitanium Full Xi FP 150 W 0.2-0.7 A, programmable
Inrush current max 53 A (50% after 300 µs)
Operational input voltage, AC 150-264 Vac

Nominal voltage, AC 220-240 Vac
Nominal voltage, DC 186-250 Vdc
Operational input voltage, DC 165-275 Vdc
Nominal input frequency 50-60 Hz
Operational input frequency 45-66 Hz
Max preprotection 16 A
Surge protection L/N-GND: 10 kV, (SR driver: 8 kV)
L-N: 6 kV
Service life min 100,000 hours
Dimming/control 8-100% programming range
Other control options DALI, Line switch, AmpDim
DALI via Zhaga book 18 socket

Variants and options

 

Item No. Nyx 450 lantern
9955- 2 x FF-DA PX, max 8,000 lm, programmable, max 75 W
9956- 3 x FF-DA PX, max 12,000 lm, programmable, max 114 W

Options
90239-2 Wall brackets

Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
4 = graphite grey 730 = 3000 K, 70 Ra
9 = silver grey 740 = 4000 K, 70 Ra
66 = noir 900 830* = 3000 K, 80 Ra
840* = 4000 K, 80 Ra
* Longer lead times

Mounting Dimming
T = post top empty = programmable
U = on arm D = Dali (4-conductor cable)
G = penetrated housing F = Phase (Line switch)
G76 = penetrated Ø76 Z = voltage (AmpDim)
R = Dali via Zhaga book 18 socket

Example Item No.: 9955-9740U = Nyx 450 2xFF-DA PX, silver grey, 4000 K, 70 Ra, for arm

Media & downloads

Photometric data

All ldt files

nyx450_svendborgteaser_1166

LED light in Svendborg Kommune

More Photos
nyx450_nat_svendborg_1166

Nyx 450 in Svendborg Kommune

More photos
nyx450_hasselager_1166

Nyx 450, Hasselager, Aarhus Kommune

nyx450_hasselagerkirke_1166

Nyx 450, Hasselager, Aarhus Kommune

nyx450_roende_l4_1166

Nyx 450 at the main street in Rønde, Syddjurs Kommune

More photos
nyx450_roende_dec2_1166

Nyx 450 at the main street in Rønde, Syddjurs Kommune

More photos
nyx450_toender14_1166

Roundabout, Tønder

More photos from Tønder.
nyx450_toender10_1166

Roundabout, Tønder

More photos from Tønder.
nyx450_odense_1166

Nyx 450, roundabout in Odense.

More photos here
skbsyd_40729_1166

Nyx 450 at 8 m column, Østjyske motorway TSA 51, Skanderborg South

skbsyd_41325_1166

Nyx 450 at 8 m column, Østjyske motorway TSA 51, Skanderborg South

skbsyd_43723_1166

Nyx 450 at 8 m column, Østjyske motorway TSA 51, Skanderborg South

nyx450_hedensted_1166

Nyx 450 at roundabout in Hedensted

nyxmaster_egtved_1166

Nyx 450 and Nyx 330 at the Egtved gas compresser station

nyx450_sauersplads_1166

Nyx 450 on angled pole, Sauers Square, Aalborg

More photos
nyx_gellerup_1141_1166

Nyx 450, Gellerup, Aarhus

nyx450_gellerup_4536_1166

Nyx 450, Gellerup, Aarhus

DesignVilhelm Lauritzen Architects

Our succes in street lighting is primarily due to the Nyx luminaires, designed by Vilhelm Lauritzen Architects in 2005.

The large lantern, NYX 450, is suitable for tall poles. It can be seen at the outdoor test centre, Living Lab at Hersted Industripark. More about the Living Lab here.