Media & downloads

NYX 330

Please choose

Nyx 330 is available for post or wall mounting. Like the other fittings in the Nyx family, it comes in black and two grey shades, both of which will fit galvanised standard poles.  

The Nyx 330 post-top luminaire is suitable for 3 to 6 meter columns. The luminaire will fit any post type with a top diameter of 60 mm.

Multiple Nyx variants are available for cylindrical columns, Ø60 mm. 

Specifications

NYX 330 POLE TOP

nyx-330-lygte

Luminaire

NYX 330 LANTERN
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: RAL 9005, SN805G, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Corten brown: YX355F, Akzo Nobel
Shade UV-resistant polycarbonate, frosted
Mounting On pole with 60 mm top diameter
Multiple Nyx Available with penetrated housing for several luminaires on 60 mm pole. See data at Media & downloads below.
Connection In the column
Focus provides 5.5 m lead 2 x 1 mm2
Classification IP65, class II; use code for class I
Impact resistance IK10; with SR socket IK09
Corrosion class C4, C5 optional
Weight 6.5 kg
Wind-sweeping area 0.053 m2 (laterally)


LED Low lumen

LED with lenses FF-DA T3 for local roads, P, HS, and C classes
Service life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen, 1xFF, 70 Ra 3000K: 450-3250 lm
4000K: 475-3500 lm
LED-lumen, 1xFF, 80 Ra 2700K: 375-2750 lm
3000K: 400-2900 lm
4000K: 410-3050 lm
Output ratio 85%
Luminous intensity class, 13201-2-2015 G*1
Glare index class D6


LED High lumen

LED with lenses FF-DA T3 for local roads, P, HS, and C classes
Service life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen, 1xFF, 70 Ra 3000K: 800-4500 lm
4000K: 900-4850 lm
LED-lumen, 1xFF, 80 Ra 2700K: 700-3800 lm
3000K: 725-4000 lm
4000K: 750-4250 lm
Output ratio 85%
Luminous intensity class, 13201-2-2015 G*1
Glare index class D6


Drivers

Driver, Low lumen Xitanium Full Xi FP 22 W 0,2-0,7 A, programmable
Inrush current max 15 A (50% after 295 µs)

Driver, High lumen Xitanium Full Xi FP 40 W 0,2-0,7 A, programmable
Inrush current max 22 A (50% after 290 µs)
Nominal voltage, AC 220-240 Vac
Operational input voltage, AC 80-264 Vac
Nominal voltage, DC 186-250 Vdc
Operational input voltage, DC 168-275 Vdc
Nominal frequency range 50-60 Hz
Operational frequency range 45-66 Hz
Max pre-protection 16 A
Surge protection L/N-GND: 10 kV, (D4i driver: 8 kV)
L-N: 6 kV
Operational life min 100,000 hours
Dimming/control 5 steps dimming within the lumen intervals
Other control options DALI-2, LineSwitch or
via Zhaga book 18 socket, D4i

Variants and options

 

Item No. Nyx 330 lantern
8914- FF-DA T3, High lumen, programmable, max 40 W
8918- FF-DA T3, Low lumen, programmable, max 26 W

Options
06034 Lamella shade
1712-1 Adapter for Ø48 and Ø42 mm post top

Double arm
8001- 2 x 400 mm, galvanised
8002- 2 x 800 mm, galvanised


Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 730 = 3000 K, 70 Ra
3 = black RAL 9005 740 = 4000 K, 70 Ra
4 = graphite grey 827* = 2700 K, 80 Ra
9 = silver grey 830* = 3000 K, 80 Ra
17 = corten brown 840* = 4000 K, 80 Ra
66 = noir 900 * Longer lead times

Dimming/control Protection class
empty = programmable empty = class II
D = DALI-2 (4/5-conductor cable) J = class I
F = LineSwitch
R = Zhaga book 18 socket, upwards
RC = Zhaga book 18 socket, City Touch / Interact City
S = Zhaga book 18 socket, downwards

Mounting Corrosion protection
empty = post top empty = C4
G = mid-column mounting C5 = C5 coating (add C5 after the colour code)


Example Product Code: 8914-66730J = Nyx 330 FF-DA T3, High lumen, noir 900, 3000 K 70 Ra, 5.5 m lead, class I

nyx-330-lygte

Luminaire

NYX 330 LANTERN
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: RAL 9005, SN805G, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Corten brown: YX355F, Akzo Nobel
Shade UV-resistant polycarbonate, frosted
Mounting On pole with 60 mm top diameter
Multiple Nyx Available with penetrated housing for several luminaires on 60 mm pole. See data at Media & downloads below.
Connection In the pole
Focus provides 5.5 m lead 2 x 1 mm2
Classification IP65, class II; use code for class I
Impact resistance IK10; with SR socket IK09
Corrosion class C4, C5 optional
Weight 6.5 kg
Wind-sweeping area 0.053 m2 (laterally)


LED Low lumen

LED with lenses FF-DA SCL for pedestrian lanes
Service life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen, 1xFF, 70 Ra 3000K: 450-3250 lm
4000K: 475-3500 lm
LED-lumen, 1xFF, 80 Ra 2700K: 375-2750 lm
3000K: 400-2900 lm
4000K: 410-3050 lm
Output ratio 80%
Glare index class D5


LED High lumen

LED with lenses FF-DA SCL for pedestrian lanes
Service life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 Kelvin
Colour rendering min 70, typically 75 Ra, 80 Ra optional*
* Longer lead times with 80 Ra
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen, 1xFF, 70 Ra 3000K: 450-4500 lm
4000K: 475-4850 lm
LED-lumen, 1xFF, 80 Ra 2700K: 375-3800 lm
3000K: 400-4000 lm
4000K: 410-4250 lm
Output ratio 80%
Glare index class D5


Drivers

Driver, Low lumen Xitanium Full Xi FP 22 W 0,2-0,7 A, programmable
Inrush current max 15 A (50% after 295 µs)

Driver, High lumen Xitanium Full Xi FP 40 W 0,2-0,7 A, programmable
Inrush current max 22 A (50% after 290 µs)
Nominal voltage, AC 220-240 Vac
Operational input voltage, AC 80-264 Vac
Nominal voltage, DC 186-250 Vdc
Operational input voltage, DC 168-275 Vdc
Nominal frequency range 50-60 Hz
Operational frequency range 45-66 Hz
Max pre-protection 16 A
Surge protection L/N-GND: 10 kV, (D4i driver: 8 kV)
L-N: 6 kV
Operational life min 100,000 hours
Dimming/control 5 steps dimming within the lumen intervals
Other control options DALI-2, LineSwitch or
via Zhaga book 18 socket, D4i

Variants and options

 

Item No. Nyx 330 lantern
8913- FF-DA SCL, High lumen, programmable, max 40 W
8919- FF-DA SCL, Low lumen, programmable, max 26 W

Options
06034 Lamella shade
1712-1 Adapter for Ø48 and Ø42 mm post top

Double arm
8001- 2 x 400 mm, galvanised
8002- 2 x 800 mm, galvanised


Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 730 = 3000 K, 70 Ra
3 = black RAL 9005 740 = 4000 K, 70 Ra
4 = graphite grey 827* = 2700 K, 80 Ra
9 = silver grey 830* = 3000 K, 80 Ra
17 = corten brown 840* = 4000 K, 80 Ra
66 = noir 900 * Longer lead times

Dimming/control Protection class
empty = programmable empty = class II
D = DALI-2 (4/5-conductor cable) J = class I
F = LineSwitch
R = Zhaga book 18 socket, upwards
RC = Zhaga book 18 socket, City Touch / Interact City
S = Zhaga book 18 socket, downwards

Mounting Corrosion protection
empty = post top empty = C4
G = mid-column mounting C5 = C5 coating (add C5 after the colour code)


Example Product Code: 8919-66830J = Nyx 330 FF-DA SCL, Low lumen, black noir 900, 3000 K 80 Ra, 5.5 m lead, class I

nyx-330-lygte

Luminaire

NYX 330 LANTERN
Material Cast aluminium
Finish Raw anodized
Graphite grey: YW355F, Akzo Nobel
Silver grey: Y2370I, Akzo Nobel
Black: RAL 9005, SN805G, Akzo Nobel
Black: Noir 900 Sablé, SN351F, Akzo Nobel
Corten brown: YX355F, Akzo Nobel
Shade UV-resistant polycarbonate, frosted or opal-white
Mounting On pole with 60 mm top diameter
Multiple Nyx Available with penetrated housing for several luminaires on 60 mm pole. See data at Media & downloads below.
Connection In the pole
Focus provides 5.5 m lead, 2x1 mm2
Classification IP65, class II; use code for class I
Impact resistance IK10; with SR socket IK09
Corrosion class C4, C5 optional
Weight 6.5 kg
Wind-sweeping area 0.053 m2 (laterally)


LED and driver data

LED type Comfort, programmable
Operational life min 100,000 hours at ta max 25° C, L100B10
Constant lumen output
Temperature range -30 to +35° C
Colour temperature 2700, 3000, or 4000 K
Colour rendering Ra 70 or 80
Colour accuracy 5 steps SDCM
Luminous flux The luminous flux range quoted below is from the LED light source. Apply output ratio to calculate luminous flux out of the luminaire.
LED-lumen, Ra 80 2700K: 285-3150 lm
3000K: 300-3300 lm
4000K: 325-3500 lm
LED-lumen, Ra 70 up to 4000 lm
Output ratio 74%
Luminous intensity class, 13201-2-2015 G*1

Driver Xitanium Full Xi FP 40 W 0.3-1.0 A, programmable
Inrush current max 22 A (50% after 290 µs)
Surge protection L/N-GND: 10 kV, (D4i driver: 8 kV)
L-N: 6 kV
Operational life min 100,000 hours
Dimming/control 5 steps dimming within the lumen intervals
Other control options DALI-2, LineSwitch or
via Zhaga book 18 socket, D4i

Variants and options

 

Item No. Nyx 330 lantern
8910- LED Comfort, programmable, max 42 W

Options
06034 Lamella shade
1712-1 Adapter for Ø48 and Ø42 mm post top

Double arm
8001- 2 x 400 mm, galvanised
8002- 2 x 800 mm, galvanised


Combine with

Select colour, colour temperature, etc. in the table below.

Colour Colour temperature
01 = raw anodized 827 = 2700 K, 80 Ra
3 = black RAL 9005 830 = 3000 K, 80 Ra
4 = graphite grey 840 = 4000 K, 80 Ra
9 = silver grey 730 = 3000 K, 70 Ra
17 = corten brown 740 = 4000 K, 70 Ra
66 = noir 900

Dimming Protection class
empty = programmable empty = class II
D = DALI-2 (4/5-conductor cable) J = class I
F = LineSwitch
R = Zhaga book 18 socket, upwards
RC = Zhaga book 18 socket, City Touch / Interact City
S = Zhaga book 18 socket, downwards

Shade type Mounting
empty = frosted shade empty = post top
O = opalised shade G = mid-column mounting

Corrosion protection
empty = C4
C5 = C5 coating (add C5 after the colour code)

Example Item No.: 8910-9830JG = Nyx 330 Comfort, silver grey, 3000 K 80 Ra, 5.5 m lead, class I, mid-column mounting

Media & downloads

Photometric data

All ldt files

nyx330_randers_0739_1166

Nyx 330, silver grey, post galvanised, Randers Kommune.

nyx330_randersview_1166

Nyx 330 at conical pole, Randers Kommune.

More Nyx in Randers
nyx330_randers_aften_1166

Nyx 330, Randers Kommune

More Nyx in Randers
horsensnaesset_1166

Nyx 330 at conical column, Næsset, Horsens.

nyx330_ejstrupholm_3_1166

The Nyx lantern is used at many local roads - here at the Municipality of Ikast-Brande.

More photos
ejstrupholm_aften_1166

Nyx 330 - Ejstrupholm, Ikast-Brande.

More photos
nyx330_vanloese_18_1166

Nyx 330 in the suburb of Vanløse, København.

More photos from Copenhagen
nyx330_vanloese_10_1166

Nyx 330 in the suburb of Vanløse, København.

More photos from Copenhagen
nyx330_svendborg_1166

Nyx 330 in Svendborg Kommune, Funen.

nyx330_kongsvang_1166

Nyx 330 in silver grey is widely used at the Aarhus Light Rail stations. Here Kongsvang south of Aarhus. 

More photos from Aarhus
nyx_alle_aften_6332_1166

Using several variants of the Nyx luminaires, the Lytt landscape architects have succeeded in designing a beautiful light setting at the Innovation Campus.

More Nyx projects
nyx330_hasselagersti_1166

Nyx 330, Hasselager, Aarhus Kommune

More Nyx at small roads
nyx330_hasselagerstinat_116

Nyx 330, Hasselager, Aarhus Kommune

More photos
nyx330_tjelevej_nat_1166

Nyx 330 LED - Herning Kommune

More Nyx 330 for pedestrians
nyx330_rds_sti_1166

Nyx 330 at low pole, Randers Kommune

More Nyx in Randers
nyx330_viborgaebleskoven_11

Nyx 330 with intelligent sensor control, Æbleskoven, Viborg

nyx330_oesterh_sti_1166

Nyx 330 silver grey at galvanisered pole, Hadsund Kommune.

nyx330_doverodde_1166

Nyx 330, corten brown, Doverodde Harbour, Thisted Kommune

nyx330_fredensborg_1166

Nyx 330 graphite grey at conical, coated pole. Architects: Arkitema

gladsaxe_redlight_1166

Fauna-friendly, red light along a cycling lane, Gladsaxe Municipality, Nyx 330 and Nyx Bollard. Photo: Rune Brandt Hermannsson, Light Bureau

nyx330_himmerland2_1166

The refurbishment of Himmerland Boligforening was headed by C.F. Møller Architects, who won the Housing of the Year prize for the project.

More photos from residential areas
nyx330_himmerland_aften_116

Light is an important part of the environment in Himmerland Tenant Association.

More Nyx in residential areas.
nyx_theresidence-05_1166

Nyx in corten brown, Enghave Waterfront, The Residence CPH, Architects: Mangor & Nagel A/S, Landscape architects: PLAN+LANDSKAB, Photo: Tom Jersø

nyx_theresidence-10_1166

Nyx in corten brown, Enghave Waterfront, The Residence CPH, Architects: Mangor & Nagel A/S, Landscape architects: PLAN+LANDSKAB, Photo: Tom Jersø

nyx330_spengelhof1_1166

Nyx 330 in residential area Spengelhof, Munich. Architects: Grabner–Huber–Lipp, Freising

More Nyx where you live
nyx330_0488_close_1166

Nyx 330 at conical design post, graphite grey. Nydamspark, Aarhus N, Kærsgaard & Andersen Architects.

More residential
nyx330_hammel_1166

Nyx 330 at low pole, Favrskov Kommune.

nyx330_frdkshvnvesterpt_116

Nyx 330 is used in many residential areas - here at Ved Vesterport, Frederikshaven.

More photos
nyx2_fyrkildevej_9332_1166

Nyx 330 silver grey - single and multiple - newly renovated residential area Aalborg East.

More Nyx in residential areas
nyx_fyrkilde_4322_1166

Nyx 330, silver grey, galvanised pole, Himmerland Boligforening. Rosseel Architects and Brix & Kamp have projected the exterior lighting.

nyx2_fyrkildevej_9353_1166

Nyx 330 silver grey at galvanised conical pole - newly renovated residential area Aalborg East.

More Nyx in residential areas
nyx330_x2_5954_1166

In the form of Multiple Nyx the Nyx luminaire becomes iconic - with and without light. 

More Nyx projects
nyx2_silver_middelfart

Multiple Nyx silver grey, Middelfart

nyx330_fredericia_1166

Nyx 330 at low poles, residential area Søndermarken, Fredericia.

nyx330_esbjerg_1166

Several variations of Nyx 330 in corten brown are used around the White House at Bryggen, Esbjerg. Architects: Friis & Moltke

More photos from Bryggen
l1009595_l_1166

Several variations of Nyx 330 in corten brown are used around the White House at Bryggen, Esbjerg. Architects: Friis & Moltke

More photos from Bryggen
nyx330x3_tingbak2_1166

Multiple Nyx is customized design at standard prices.

More examples with Multiple Nyx
nyxmultiple_esbjerg_1166

Multiple Nyx 330 in corten brown  - icons around the White House, Bryggen Esbjerg.

More photos from Bryggen
l1009529_p_1166

Multiple Nyx 330 in corten brown  - icons around the White House, Bryggen Esbjerg.

More photos from Bryggen
multiplenyx_square_7618_116

Multiple Nyx 330 in corten brown, public school at Sundbyøster

multiplenyx_6300_1166

Both Nyx 330 and Multiple Nyx can be seen in the area around the International School at Ikast. C.F. Møller Architects have created a visionary environment for culture and learning. 

More images from Ikast
nyx_6338_1166

The Nyx luminaires are silver grey, whereas the posts are white. The design adds character to the environment and the lamp posts become sculptures.

More images from Ikast
nyx330_x3_aften_6253_1166

Multiple Nyx adds an extra dimension to lighting design, and by the combination of one, two, or three luminaires at a pole, variation is added to the minimalist design.

More Nyx projects

DesignVilhelm Lauritzen Architects

The story of Nyx begins in 2004 when Vilhelm Lauritzen Architects present the first draft for a wall fitting in two sizes. The design was simple, but characteristic and easily recognisable. Furthermore, Nyx differed from other luminaires of the time by the fact that it is cast in aluminium. Soon the series grew by lanterns and bollards, and especially the lanterns have shown great potential in street lighting.

More about Vilhelm Lauritzen Architects here.